Features
  • Designed to insert in the patient's vein to give anaesthesia, medicine or other solutions for intermittent drug therapy, infusion or multiple fluid infusion.
  • 100% safe: It can be used without risk of thrombophelebitis because it is made of P.T.F.E. (Poly Tetra Fluoro Ethylene) catheter, one of the most bio-compatible materials known to man. P.T.F.E. has the lowest coefficient of friction and reduces the chances of sticking to vascular walls.
  • The P.T.F.E. catheter, designed and made with double tapered formed tip and siliconised, offers lower resistance during insertion, resulting in less trauma to the patient, avoiding fold back.
  • Air vented hub: The needle end is covered with a unique air vented hub (fitted on Needle hub) resulting in a higher flow rate and quick and easy confirmation of correct vascular access. It avoids blood spillage and prevents formation of air bubbles.
quality


I. V Cannulae - ProveinTM
This type of IV Cannulae comes with wings and an injection valve to provide extra medication without pain. Specially designed cap on the top prevents contamination when the valve is not in use.

IV Cannula
Lars Medicare
Gauge Colour Int.-Ext. Dia(in mm) Length (in mm) Water flow (in ml/minute)
14 Brown 1.6-2.1 45 270
16 Grey 1.3-1.7 45 180
17 White 1.2-1.5 45 125
18 Green 0.9-1.3 45 90
20 Pink 0.8-1.1 32 60
22 Blue 0.6-0.9 25 36
24 Yellow 0.5-0.7 19 20
26 Violet 0.4-0.6 19 13



I. V Cannulae - Provein Lars Medicare TM
It's a "Pen type" Cannula without injection valve and wings.
Long and broad needle hub for a perfect grip and control.
Best for cases with high risk of infection from additional openings in the Cannulae.

IV Cannula
Lars Medicare
Gauge Colour Int.-Ext. Dia(in mm) Length (in mm) Water flow (in ml/minute)
14 Brown 1.6-2.1 45 270
16 Grey 1.3-1.7 45 180
17 White 1.2-1.5 45 125
18 Green 0.9-1.3 45 90
20 Pink 0.8-1.1 32 60
22 Blue 0.6-0.9 25 36
24 Yellow 0.5-0.7 19 20
26 Violet 0.4-0.6 19 13
Vandana Impex Vandana Impex



I. V Cannulae - Provein ßTM
This type of IV Cannula comes with wings but without injection valve.
It is best for cases with high risk of infection from additional openings in the Cannulae.

IV Cannula
Lars Medicare
Gauge Colour Int.-Ext. Dia(in mm) Length (in mm) Water flow (in ml/minute)
14 Brown 1.6-2.1 45 270
16 Grey 1.3-1.7 45 180
17 White 1.2-1.5 45 125
18 Green 0.9-1.3 45 90
20 Pink 0.8-1.1 32 60
22 Blue 0.6-0.9 25 36
24 Yellow 0.5-0.7 19 20
26 Violet 0.4-0.6 19 13



Vandana Impex Vandana Impex




Provein Neo I.V. Cannulae
This type of IV Cannulae comes with wings but without injection valve.
It is best for cases with high risk of infection from additional openings in the Cannulae.
Lars Medicare
Gauge Colour Int.-Ext. Dia(in mm) Length (in mm) Water flow (in ml/minute)
14 Brown 1.6-2.1 45 270
16 Grey 1.3-1.7 45 180
17 White 1.2-1.5 45 125
18 Green 0.9-1.3 45 90
20 Pink 0.8-1.1 32 60
22 Blue 0.6-0.9 25 36
24 Yellow 0.5-0.7 19 20
26 Violet 0.4-0.6 19 13



Pro Way stop cockTM

Lars Medicare3-Way Stop Cock facilitates multiple lines through single IV access.

Fully transparent body made of medical-grade biocompatible polycarbonate allows visualization of fluids.

Universal 6% taper on luers allows connection with a wide variety of standard medical devices.

Tested for smooth, laminar and leak-proof flow up to 3 bars pressure

Superior quality 3-Way Stop Cock now available with integrated extension tubing also.
It is available in lipid resistance also


PROEXT TM– WITH EXTENSION TUBE

Extension tube provides separation of administration and insertion sites.

Minimizes mechanical irritation of blood vessel being used for access
Reduces thrombotic events such as thrombophlebitis
Increase patient comfort
Ideal for administering contrast medium/fluids during imaging procedure that require patient to enter a gantry; e.g/ CT and MRI Scans
High quality Kink-resistant tubing with smooth inner surfaces for laminar, non turbulent flow.
Available in various tube lengths based on customer requirements.



Luer lock

Luer cap with universal 6% taper as per ISO594.

Blister packed and sterile


Profist Needle

AV Fistula Needle allows venous and arterial access for patients undergoing hemodialysis
Ultra-thin wall stainless steel needle (with or without back-eye)
siliconized on both internal and external surfaces
Provides optimum penetration profile
Minimizes pain during insertion, Maximizes smooth, laminar flow
USP Class VI soft, kink-resistant tubing made from medical-grade PVC
Rotating, color-coded wings facilitate flipping of needle while allowing for easy gripping and fixation
Orientation dot on needle hub enables precise maneuvering of bevel
Luer has universal 6% taper to allow smooth connection with Standard bloodline sets
Available in single pack or twin-pack for better use of space
Available "with" or "without" Back-Eye needle.
Available with Red, Blue or White Clamp.
Available with 15 cm or 30 cm Tubing
Sizes: 15 G, 16 G & 17 G



Injection Stopper

Generally used for taking blood samples with the help of syringe and needle.
To Stop I.V. Cannulae when not in use
Integrated valve within the stopper to allow drug administration into the Cannulae without unscrewing it.
Universal 6% taper as per ISO 594, compatible with any standard product.
Minimum dead space
Latex free option also available
Blister packed and sterile



- Packaging & Logistics Assistance Services
With our extensive industry experience we recognize that quality in itself encompasses the complete system of product delivery & not just manufacturing standardized products. Consequently, we assist our clients at every step rather than transferring the liability of packaging & logistics to our clients.

Our expertise in offering export quality packaging helps us in protecting the consignments from the hazards of overseas shipping. Our packaging creates moisture barriers and inhibitors, it provides cushioning materials to protect from against shock and vibration, clear labels for easy identification, prevent mishandling and ensuring the safe delivery of your product.

We have tie-ups with internationally renowned C&F companies for fast & timely deliveries. Our value-added logistics assistance has enabled us to assure our clients of flawless products, delivered on-time.
- OEM / Private Labelling
With our state-of-the-art manufacturing facility & allied supports, we are capable of executing Private Labelling assignments, where we manufacture products as per the buyer's specification, and these products are marketed by the Buyer or by the Private Labeller.

The implementation process includes various phases: sourcing/producing raw material, preparing sub assemblies, final assembling, QC checks, packaging & allotment of batch number, logistics and safe product delivery. We also have the facility to offer custom ready-to-sell packaging to our clients.
- Customized Product Development
We work in congruence with our clients to integrate raw material utilization, product design and manufacturing processes, to minimize costs and deliver customized products & services. Our streamlined processing experience, enables us to meet the specific demands of our client within the stipulated time frame.
- On - Time Delivery / Shipping Information
Scheduled delivery & up-to-date communication regarding the shipping information is one of the ways to measure our performance. We, assure on-time delivery for small and large/bulk consignments alike.



- Instruction for Use
PROVEIN I.V. CANNULA WITH P.T.F.E. NATURAL/ RADIO OPAQUE CATHETER WITH INJECTION VALVE WITH WINGS.

MATERIAL USED:
Radiopaque strip/Natural PTFE, PP,POM & Stainless Steal.

INDICATION:
Infusion of I. V. Solutions.
Intermittent Intravenous drug administration.
To maintain hydration and/or correct dehydration if patient is unable to take sufficient volume of oral fluids.

CONTRAINDICATION:
Product should not be used on patient with known hypersensitivity to any of the material used.
Administration of high viscous fluid.
Large blood transmission.

INSTRUCTION FOR USE:
1. Carefully select and aseptically prepare the site.
2. Select suitable size of cannula & inspect visually to ascertain that package is intact.
3. Remove cannula from sterile packing & remove its needle from cover.
4. Grip the cannula from protection provided on body & hub.
5. Perform venipuncture & check for flash back of blood in flash back chamber.
6. Advance the catheter in to the vein and simultaneously withdrawn the needle.
7. Withdraw the needle completely while pressing the site just the tip of catheter into the vein & discard the needle in an appropriate container.
8. Connect to the I.V. Infusion set.
9. Cover the puncture site with sterile dressing.
10. Drug can be injected with the help of syringe without needle through integrated injection port after removing the port cap.
11. Pressure on the plunger of syringe during the injecting of drug should not be more and movement of plunger should be smooth & regular.
12. Close the port cap thereafter.
13. Perform routine monitoring & venipuncture site maintenance according to medical norms.

CAUTION:
NEVER TRY TO REINSERT THE PARTIALLY OR COMPLETELY WITH DRAWN NEEDLE.
DISPOSE OFF SAFELY AFTER USE AWAY FROM LIVING BEING.

WARNING:
The use of this product is restricted to a qualified doctor or a paramedic.
Read instruction before use.
The product should be used according to the instructions for use.
The product should not be reprocessed.
Visually inspect and carefully check the product and packaging before use.
Improper transport and handling may cause structural and /or functional damage to device or packaging.
The product is guaranteed non-toxic, sterile & non-pyrogenic if the package has not been opened or damaged.
Do not clean or resterilise.
For single use only.
Discard after use.
Store in dry & cool place.
Do not expose to heat or direct sunlight.
The product should be used immediately after opening the packaging.
Lars Medicare disclaim any responsibility for possible consequences resulting from improper use.

- Packaging Details

S.No. Description Qty. in Inner Box in Pcs. Export Master Box Quantity Per 20 Ft. Container Quantity Per 40 Ft. Container Quantity Per 40 Ft. High Cube Container
Qty. in Master Box in Pcs. Size (Cm.) Weight in Kgs. CBM. Per Export Master Box
L W H Volume Net  Gross
1 I. V. Cannula with Injection Port with Wings                      Brand : Provein       
Size: 14, 16, 17, 18, 20, 22 & 24G
100 1000 69.8 32.0 17.8 6.60 5.10 6.30 0.0397 750,000 1,500,000 1,800,000
2 I. V. Cannula without Injection Port with Wings                  Brand :Provein Beta / Provein Neo
Size: 14, 16, 17, 18, 20, 22 & 24G
100 1000 69.8 32.0 17.8 6.60 5.10 6.30 0.0397 750,000 1,500,000 1,800,000
3 I. V. Cannula without Injection Port without Wings            Brand : Provein Alpha     Size: 14, 16, 17, 18, 20, 22 & 24G 100 1000 46.0 30.0 20.0 4.60 3.50 4.80 0.0276 1,100,000 2,100,000 2,700,000
4 3 way Stop Cock 50 500 53.8 29.0 18.0 4.60 2.60 3.70 0.0281 5,05,000  10,10,000  11,30,000 
5 3 way with extension tube 50 500 43.0 40.0 49.0 4.60 3.50 4.80 0.0843 1,70,000  3,40,000  3,80,000 
6 A.V.F 50 500 67.0 46.0 28.0 8.50 3.50 4.80 0.0863 1,50,000 3,00,000  3,35,000 
7 LUER LOCK 500 5000 69.8 32.0 17.8 6.60 5.10 6.30 0.0397 3,750,000 7,500,000 9,000,000

- Storage Conditions
Store in a cool and dry place, do not expose to heat or direct sunlight.


- Expiry
5 years from the date of manufacturing.



-